XMM-Newton SAS Home Page
XMM-Newton Science Analysis System


emsaplib (emsaplib-2.29.1) [xmmsas_20141104_1833-14.0.0]

pat_init edusoft_mod module badpixutils_mod module Home Index

Meta Index / Home Page / Description / edusoft_mod module

edusoft

This is the EDUSOFT call.

The F90 calling sequence is:

! Input arguments :

 integer :: edumode                       ! 0  diagnostic mode
                                          ! 1  timing mode
                                          ! 2  reduced imaging (threshold) mode
                                          ! 3  imaging mode  
 
 type(edu_pattern)   :: edupat(edu_npat)  ! initialized by pat_init().
 integer(kind=int32) :: dx                !  x size of the input image.
 integer(kind=int32) :: dy                !  y size of the input image.
 integer(kind=int16), dimension(dx,dy) :: im  ! input image.
 integer(kind=int16) :: threshold         ! EDU threshold.

! x EDU offset (must contain at least x0+dx data).
 integer(kind=int16), dimension(0:x0+dx-1) :: offX

! y EDU offset (must contain at least y0+dy data).
 integer(kind=int16), dimension(0:y0+dy-1) :: offY

! x coordinate of the closest pixel to the output CCD node.
 integer(kind=int32) :: x0  

! y coordinate of the closest pixel to the output CCD node.
 integer(kind=int32) :: y0  
                      
! es_nmax : Maximum number of events that can be found in a frame by EDUSOFT.
!           (See declaration subsection).

! Output argument :

! Data structure containing the EDUSOFT output event list.
 type(edu_out)  :: eduout

 
 call edusoft(edumode,edupat,dx,dy,im,threshold, &
              offX(0:x0+dx-1),offY(0:y0+dy-1),x0,y0,es_nmax,eduout)



XMM-Newton SOC/SSC -- 2014-11-04