XMM-Newton Science Analysis System
esensmap (esensmap-3.12) [xmmsas_20141104_1833-14.0.0]
Meta Index / Home Page
Description
This task creates a sensitivity map giving point source detection
upper limits (vignetting corrected source count rate corresponding to the
likelihood of detection as specified in the parameter file) for each
image pixel.
The task may either be called for individual energy bands or combinations
of energy bands and instruments.
The upper limits are calculated by assuming Poissonian
count statistics in each 3
3 pixel detection cell, using the
exposure and background values read from the input images. It is assumed
that 30 upper limit calculation is meant as a reference point for a more detailed
assessment of the sensitivity of the detection process to be
determined through Monte Carlo simulations.
In the case of multiple input energy bands the upper limits are
expressed in units of counts per seconds for the combined band
(i.e. they refer to the detection sensitivity which would be
acchieved by adding up the photons observed in the individual bands).
Pixels outside of the detection mask used by the eboxdetect
detection task as well as pixels with zero exposure time are
assigned a sensitivity value of -1.0. This also holds for pixels
where - due to a failure of the esplinemap backgound task - zero
or negative values occure in the input background maps.
XMM-Newton SOC/SSC -- 2014-11-04