XMM-Newton Science Analysis System
rmfgen (rmfgen-2.2.1) [xmmsas_20160201_1833-15.0.0]
Meta Index / Home Page / Algorithm
EBOUNDS table creation
- Write header information for EBOUNDS table
- Get the channel ranges from the CAL and attempt to
rebin them for the input spectrum. If this fails:
For each spectrum channel,
compute the values of the columns E_MIN
and E_MAX from the
PI channel range corresponding to that channel.
- Write EBOUNDS data to file
XMM-Newton SOC/SSC -- 2016-02-01